Two gloves can share the same knitted liner and still behave differently because the palm coating is the part that touches the work. Polyurethane (PU) is often applied as a thin, close-fitting layer for dry precision handling. Nitrile coatings are commonly selected when abrasion, oil contact or a more substantial grip surface matters.
That is a useful starting point—not a universal ranking. “PU” and “nitrile” identify polymer families, but they do not reveal coating thickness, porosity, surface finish, coverage or the finished glove’s test results.
The short comparison
| Question | PU-coated glove | Nitrile-coated glove |
|---|---|---|
| Typical design emphasis | Low bulk and fingertip tactility | Mechanical durability and oily-work options |
| Common surface | Thin, smooth palm coating | Smooth, foam, micro-foam or sandy texture |
| Typical starting environment | Dry to slightly oily precision handling | Dry, oily or intermittently wet handling, depending on construction |
| Liquid behaviour | Not established by “PU” alone | Often better suited to oil contact, but not automatically liquid-proof |
| Main variable buyers miss | A thin coating can wear differently from a thicker one | Foam, texture and full/palm coverage change performance substantially |
The word typical matters. A high-performing PU glove can outscore a nitrile glove in an abrasion test, while a carefully engineered nitrile glove can be thin and highly dexterous. Compare actual products, not stereotypes.
Why PU often feels more precise
For a worker to feel a small edge or align a fastener, the glove must bend with the finger and transmit shape through the palm. A thin PU film adds relatively little bulk between the hand and the part. On fine-gauge knitted liners, it can preserve close fit at the fingertips.
This is why PU-coated gloves frequently appear in small-parts assembly, inspection, electronics handling and packaging. As one product-specific example, Ansell describes its 15-gauge PU-coated EDGE 48-125 as a high-tactility glove for dry to slightly oily work and reports EN 388:2016+A1:2018 performance of 4121A. In that code, the glove achieved level 4 abrasion, level 1 Coup cut, level 2 tear, level 1 puncture and TDM cut level A—five separate results, not one overall score.
That example proves something important: thin does not mean untested or automatically weak. It does not prove that every PU glove reaches abrasion level 4. The liner, coating formulation, thickness, adhesion and complete glove construction all contribute to the result.
Why nitrile has more versions for oily work
Nitrile is available in several coating builds. A smooth, relatively closed film can reduce oil reaching the liner at the coated area. A foam or micro-foam surface creates more edges and voids that can help manage a thin oil film. A sandy finish adds a more aggressive texture for heavier handling.
These designs answer different questions:
- Smooth nitrile: how much of the palm is covered by a continuous film?
- Foam nitrile: how does the contact surface behave around a light liquid film?
- Sandy nitrile: is a rougher mechanical contact surface useful for the part and task?
- Double-dipped nitrile: does a base coat provide coverage while a second palm coat supplies grip?
Our separate guide to smooth, foam and sandy nitrile coatings explains these surfaces in more detail.
Oil resistance and oily grip are not the same result
A glove can slow oil from contacting the knitted liner yet still slide on an oily component. It can also grip an oily part effectively while offering only limited liquid coverage on the back of the hand.
Oil resistance concerns the barrier behaviour of the coated area. Oily grip concerns friction at the glove–oil–part interface. Coverage, film continuity and material affect the first; surface texture, oil volume, contact pressure and part geometry strongly affect the second.
Ansell’s current data sheet for its nitrile-coated EDGE 48-128, for example, describes oil resistance and grip for light applications and identifies a 13-gauge polyester liner with a palm nitrile coating. Those statements apply to that finished product—not automatically to every nitrile-coated glove.
Do not assign a protection level from the polymer
Neither PU nor nitrile creates an automatic ANSI/ISEA 105 or EN 388 rating. These systems evaluate the finished glove under defined test methods. Liner yarn, knit gauge, reinforcement, coating and manufacturing consistency are tested together.
| Claim on a product page | What should support it |
|---|---|
| Abrasion resistance | Product-specific ANSI/ISEA 105 or EN 388 result |
| Cut resistance | Product-specific cut rating and applicable test method |
| Puncture resistance | Product-specific puncture result; do not confuse it with needlestick resistance |
| Chemical resistance | Chemical-specific permeation and degradation information |
| Oily grip | Task-relevant product evidence or a controlled workplace trial |
OSHA requires US employers to select hand protection from the glove’s performance relative to the task, conditions, duration and identified hazards. Its guidance also lists dry, wet or oily grip, dexterity, exposure frequency and physical stress as separate selection factors. A coating-family label cannot replace that assessment.

A practical comparison sequence
Start with the work surface:
- Dry, clean and small: evaluate a thin PU-coated glove first when tactile control and low bulk are priorities.
- Light oil film: compare a purpose-designed nitrile texture with a suitable PU product rather than eliminating either material by name.
- Repeated oil or wet contact: examine nitrile coating continuity, coverage and cuff boundary—not only palm texture.
- Sharp edges: compare the finished gloves’ cut, abrasion and puncture ratings independently of coating material.
- Chemical exposure: leave the general-purpose comparison and use chemical-specific compatibility data for the exact formulation, concentration, temperature and contact time.
Then compare candidates with the same liner gauge, similar coverage and similar fit where possible. Otherwise, a thick 13-gauge nitrile glove and an ultralight 18-gauge PU glove are answering different design briefs, so attributing every difference to the polymer would be misleading.
Which coating should you start with?
| Work pattern | Sensible first candidate | Why it is only a starting point |
|---|---|---|
| Inspecting clean machined parts | Thin PU palm coating | Confirm abrasion rating, cleanliness needs and part-marking risk |
| Picking small dry fasteners | Fine-gauge PU palm coating | Fit and fingertip construction can matter as much as polymer |
| Handling lightly oily components | Textured or foam nitrile palm coating | Oil volume and surface geometry can change grip |
| Reaching around oily assemblies | Three-quarter or fully coated nitrile construction | Coverage boundary and film continuity still require checking |
| Handling sharp oily sheet metal | Cut-resistant liner plus task-suitable nitrile coating | Coating does not create the cut rating by itself |
PU is often the efficient starting point for clean precision work; nitrile offers a broader set of constructions for oil contact and heavier handling. The final choice should match the complete construction and verified results to the real contact condition.
Technical references
- OSHA — Hand protection, 29 CFR 1910.138
- OSHA — Dermal exposure: control and prevention
- Ansell — EDGE 48-125 PU-coated glove
- Ansell — EDGE 48-128 nitrile-coated glove data sheet
- ArmorHive — Smooth vs Foam vs Sandy Nitrile-Coated Gloves
- ArmorHive — Palm-Dipped vs Three-Quarter-Dipped vs Fully Dipped Work Gloves
This article explains general construction principles. Verify the exact glove’s test results, instructions and suitability for the workplace hazard before selection.