A biohazard pictogram on a glove package can look like a broad promise. Under ISO 374-5:2024, however, the marking communicates a specific set of laboratory requirements. The most important detail may be a single word printed beneath the symbol: VIRUS.
Without that word, the marking covers protection against bacteria and fungi under the standard’s penetration requirements. With VIRUS, the glove must also meet a separate viral-penetration test using a bacteriophage challenge.
This distinction is easy to miss—and it is the reason two boxes carrying similar biohazard symbols may not support the same claim.

First, check the edition: 2024 replaced 2016
ISO published ISO 374-5:2024 in July 2024 as the second edition. It replaced the 2016 edition, which ISO now lists as withdrawn. The core purpose remains the same: setting requirements and test methods for protective gloves intended to protect the user against microorganisms.
The 2024 revision is more than a date change. ISO identifies these principal updates:
- alignment with ISO 21420:2020+Amd 1:2022 for general glove requirements;
- a new dexterity requirement;
- updated protection-type requirements;
- an additional marking possibility; and
- clearer manufacturer-information rules for single-use gloves.
Older certificates and packaging may still cite the 2016 edition during market transition. That does not automatically make the glove ineffective, but a current purchase specification should identify the standard edition and certification basis rather than treating “ISO 374-5” as timeless.
The two marking outcomes
ISO 374-5 separates microorganism protection into two claim levels.
| Marking outcome | Bacteria | Fungi | Viruses | Additional viral test |
|---|---|---|---|---|
| Biohazard pictogram + ISO 374-5 reference | Yes | Yes | Not claimed | No |
| Biohazard pictogram + ISO 374-5 reference + VIRUS | Yes | Yes | Yes, under the specified test conditions | ISO 16604 using Phi-X174 bacteriophage |
The word VIRUS is therefore not decoration. It indicates that the viral requirement was added to the bacteria-and-fungi requirements. A plain biohazard pictogram must not be mentally upgraded into a virus claim.
The reverse is also important: VIRUS does not mean protection against only viruses. Under the standard, it identifies the higher of the two microorganism marking outcomes—viruses, bacteria and fungi.
The base requirement: finding holes by penetration testing
For bacteria and fungi, ISO 374-5 uses penetration testing associated with ISO 374-2. In standards terminology, penetration is movement through non-molecular openings such as holes, seams or other imperfections. It is different from permeation, where a chemical moves through a material at the molecular level.
Two leak methods are used to detect physical pathways:
| Method | Basic principle | What a failure suggests |
|---|---|---|
| Air-leak test | The glove is pressurized with air and inspected for escaping bubbles while immersed in water | A hole, weak seam or other continuous pathway through the glove |
| Water-leak test | The glove is filled with water and inspected for leakage | A pathway large enough for water to pass under the test conditions |
These methods are practical because an intact continuous barrier is the foundation of microorganism protection. They do not grow bacteria or fungi on the glove, measure antimicrobial activity, or prove that the glove kills microorganisms.
Passing means that the tested samples did not leak under the specified procedure. It does not mean every glove in every production lot is individually laboratory-tested, and it does not eliminate the possibility of damage during donning or use.
What changes when VIRUS appears
Viruses can be far smaller than bacteria and may pass through pathways that are not obvious in an ordinary visual inspection. To support the VIRUS marking, ISO 374-5 requires testing according to ISO 16604 with Phi-X174 bacteriophage.
Phi-X174 is a virus that infects bacteria rather than humans. It is used as a surrogate challenge because it is small, detectable through a biological assay and suitable for controlled barrier testing.
The glove-material specimen is mounted in a penetration cell. A liquid suspension containing Phi-X174 contacts one side while the method applies a defined exposure and pressure sequence. Fluid collected from the other side is assayed for the bacteriophage. The requirement is no detectable transfer, reported at less than 1 plaque-forming unit per millilitre (PFU/ml) in the assay titre.
| Test element | Why it matters |
|---|---|
| Liquid challenge | Evaluates a blood/body-fluid contact pathway, not dry airborne filtration |
| Phi-X174 bacteriophage | Provides a small, measurable viral surrogate |
| Controlled pressure | Challenges the material more consistently than visual inspection alone |
| Biological assay | Can detect viral penetration even when no liquid leak is visible |
The result is a pass/fail barrier result. It is not a percentage filtration rating and it does not assign a virus-protection level from 1 to 5.
Where the 2024 edition takes test specimens
Sampling location matters because glove construction is not always uniform. ISO 374-5:2024 specifies that the viral-penetration specimen is taken from the palm area.
Additional locations become relevant in two cases:
| Glove feature | 2024 sampling implication |
|---|---|
| Hand-area seam | The seam area must be tested |
| Glove length at least 400 mm, with the cuff claimed for microorganism protection | Additional specimens are taken near the cuff, with the centre approximately 80 mm from the cuff end |
This prevents a long protective cuff or a seam from being covered by a claim based only on an easier, uninterrupted part of the glove. It also explains why the exact claimed protective area should be checked in the manufacturer’s instructions.
The new dexterity requirement
ISO 374-5:2024 adds a dexterity subclause linked to ISO 21420. The glove must achieve at least dexterity performance level 1, while providing as much dexterity as its intended use permits.
In the ISO 21420 pin-pickup method, higher levels correspond to handling smaller pins. Level 1 is the entry threshold; it should not be interpreted as evidence of high-precision fingertip control.
| Dexterity result | Plain-language meaning |
|---|---|
| Meets level 1 | Satisfies the minimum dexterity requirement used by ISO 374-5:2024 |
| Higher ISO 21420 level | The glove handled a smaller test pin under that method |
| No task trial | The laboratory result still does not predict performance with every tool, grip or wet surface |
Barrier protection and dexterity can pull in opposite directions. A thicker or longer glove may improve coverage but reduce tactile control. The new minimum helps prevent a protective claim from ignoring basic usability; it does not replace a workplace trial.
What the marking does not tell you
ISO 374-5 is narrowly focused. The microorganism symbol alone does not answer several other safety questions.
| Question | Is it answered by ISO 374-5 alone? | Where to look instead |
|---|---|---|
| Does the glove resist a specific disinfectant or solvent? | No | ISO 374-1 permeation classification and chemical-resistance data |
| Does contact with a chemical weaken the glove? | No | ISO 374-4 degradation results |
| Is it cut or puncture resistant? | No | ISO 23388/EN 388 or another applicable mechanical standard |
| Is it approved for a particular medical use? | No | Applicable medical-device regulation and product claims |
| Does it filter aerosols or protect the respiratory tract? | No | Relevant respiratory-protection standards |
| Will it remain intact for an entire shift? | No | Task-specific wear time, inspection and replacement rules |
This is also why the VIRUS marking should not be presented as a universal “virus-proof” statement. The laboratory test evaluates penetration through the tested glove material and relevant sampled features under specified conditions. Real use adds stretching, fingernail damage, abrasion, incorrect sizing, contaminated removal and chemical exposure.
ISO 374-5 versus ASTM F1671
Both systems can use Phi-X174 bacteriophage to evaluate viral penetration, but they serve different purposes.
| Point | ISO 374-5:2024 | ASTM F1671/F1671M |
|---|---|---|
| Role | Product requirements and marking framework for microorganism-protective gloves | Test method for protective-clothing materials against blood-borne pathogen penetration |
| Basic microorganism claim | Includes bacteria/fungi penetration requirements | Not a bacteria/fungi glove-marking system |
| Virus test reference | Calls up ISO 16604 | Defines its own Phi-X174 test method |
| Marking result | Can authorize the microorganism pictogram with VIRUS when all requirements are met | A test report does not by itself create the ISO 374-5 marking |
| Additional requirements | Includes general requirements, sampling, dexterity and manufacturer information | Focuses on the viral-penetration test procedure |
The presence of a similar surrogate does not make the standards interchangeable. A supplier should state which standard was tested, which edition applies and whether the claim covers the finished glove or only a material specimen.
A five-step label check
When comparing products, use the marking as the start of the review rather than the end.
1. Find the standard reference. Confirm that the label or instructions cite ISO 374-5 and note the edition. 2. Look below the pictogram. If VIRUS is absent, do not assume viral penetration testing. 3. Check the protective area. For long gloves, verify whether the cuff is included in the microorganism claim. 4. Read the manufacturer’s limitations. The instructions should explain that laboratory penetration resistance may not represent workplace conditions. 5. Match the other hazard. Add chemical, mechanical, thermal or medical requirements according to the task.
The key point
ISO 374-5:2024 does not turn one biohazard symbol into a blanket statement. It creates two readable outcomes. The standard microorganism marking addresses bacteria and fungi through penetration requirements. The same marking with VIRUS adds a Phi-X174 viral-penetration challenge under ISO 16604.
For the buyer, the simple rule is useful: read the word beneath the symbol, then read the limitations behind it. That small check separates a documented virus claim from an assumption—and helps ensure the glove is evaluated against the actual workplace hazard.
Technical references
1. International Organization for Standardization. ISO 374-5:2024 — Protective gloves against dangerous chemicals and micro-organisms — Part 5: Terminology and performance requirements for micro-organisms risks. https://www.iso.org/standard/83211.html 2. International Organization for Standardization. ISO 374-5:2016 (withdrawn; replaced by ISO 374-5:2024). https://www.iso.org/standard/66562.html 3. International Organization for Standardization. ISO 374-2:2019 — Determination of resistance to penetration. https://www.iso.org/standard/70072.html 4. International Organization for Standardization. ISO 16604:2004 — Resistance of protective clothing materials to penetration by blood-borne pathogens using Phi-X174 bacteriophage. https://www.iso.org/standard/32248.html 5. Instituto Nacional de Seguridad y Salud en el Trabajo. Protective gloves against microorganisms: selection and use guidance. https://www.insst.es/documentacion/colecciones-tecnicas/fichas-de-seleccion-y-uso-de-epi-fsu-epi/guantes-de-proteccion-frente-a-microorganismos